What the agency is buying
by RFPFinder from the notice and attachments; the solicitation governsThe Department of Veterans Affairs seeks preventative and corrective maintenance on nurse call systems at Providence VA Medical Center. This is a sole-source procurement evaluated on capability statements.
Scope
- Preventative and corrective maintenance on Rauland Responder nurse call systems
- Biannual functional assessments, upgrades, and electronic service reporting
How to get the bid documents
- Download the 2 documents below (no portal account needed)
- Check the submission requirements in the compliance checklist
- Submit by email before 12:00 PM ET on Oct 13
Details
- Place of performance
- TOGUS, Maine
- Buyer type
- Federal
- Notice type
- Special Notice
- Solicitation no.
- 36C241-26-Q-0857
- Size standard
- $37M revenue SBA table, NAICS 541513
- Delivery location
- Providence VA Medical Center, 830 Chalkstone Avenue, Providence, RI 02908 from notice
- Period of performance
- 1-year base period plus 4 one-year option periods from notice
- Contract type
- Sole-source from notice
- Approved sources
- SIGNET Electronic Systems, LLC from notice
- Local presence
- Required
- Amendments
- None since Oct 7
- Contact
- Rosangela Pereira · Contract Specialist
- Office
- 241-NETWORK CONTRACT OFFICE 01 (36C241)
- Phone
- 401-273-7100
Not stated in the notice: estimated value. Check the bid documents.
Contact details from the source notice. Contact the buyer only about this solicitation.
Key dates
Change log
verified Sun, Oct 11 · 12:30 AM ETNo amendments since posting on Wed, Oct 7; verified Sun, Oct 11 · 12:30 AM ET.
Report a problem
Notice as published
J065--Nurse Call Systems Maintenance
The Department of Veterans Affairs, Networking Contracting Office (NCO
- located in Providence, RI intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with SIGNET Electronic Systems, LLC for the following requirement: Performance Work Statement Nurse Call Systems Maintenance Summary/Requirements: The contractor shall provide preventative and corrective maintenance on the nurse call systems installed at the Providence VA Medical Center in the following locations: Building 1/Area Responder Version ED Responder 4 OR/Clean Core/PACU Responder 4 Hemo/ICU Responder 5 3B Responder 5 4A Responder 5K 4B Responder 5 5B Responder 5 6A Responder 5 6B Responder 5 B-39 Responder 5 MRI Addition (In Construction) Responder 5 The scope of service provided is as follows: The contractor shall provide next business day service.
Labor, mileage, and trip charges shall be included. The contractor shall perform a biannual functional assessment of each system outlined above and shall provide a report outlining the satisfactory/unsatisfactory test status of each system and end device. A follow-on plan with associated proposal for parts necessary to return the system to fully satisfactory condition shall be provided to the customer.
Labor, mileage, and trip charges associated with the above outlined repairs will be included in the service contract. Base year will include the upgrade of the ED and OR/Clean Core/PACU Responder 4 systems to Responder 5K to allow the systems to be fully supported into the future. This process includes all labor, materials, programming and engineering by the contractor to satisfy this requirement.
Base year will include the addition of nurse call components necessary to bring rooms 460, 469, and 485 into clinical compliance for nurse call. This process includes all labor, materials, programming and engineering by the contractor to satisfy this requirement. The contractor shall provide an electronic service report for all preventative and repair work whether scheduled service or call-in repair work within 24 hours of the completion of the work order.
Qualifications of Contractors The contractor shall be within 60 miles of the Providence VA Medical Center. The contractor shall be factory authorized and entitled to supply, install, and service the Rauland Responder 4, 4K, 5, and 5K nurse call systems and have full factory warranty privileges. Place of Performance VAMC Providence 830 Chalkstone Avenue Providence, RI 02908 Period of Performance The contract period of performance is one-year base period plus four one-year option periods.
The NAICS code for this requirement is 541513. SIGNET Electronic Systems, LLC is the only authorized Rauland Responder Nurse Call distributor that can supply, install, service, and has full warranty privileges in the New England region. SIGNET is authorized to supply, install, and service the Rauland Responder 4, 4K, 5, and 5K nurse call systems and have full factory warranty privileges.
This notice of intent is not a solicitation nor is it a request for proposal. However, all responsible sources may submit a capability statement demonstrating the ability to provide the requested services, in writing by Tuesday, October 13, 2026 at 12PM EST. Responses should be sent to Rosangela Pereira at [email on the source notice].
Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination not to open the requirement to competition based upon responses to this notice is solely within the discretion of the Government.
What this office paid before
USAspending.gov, last 36 months25 awards matched · tier 1: this contracting office (36C241) + PSC J065. Most recent:
Pro shows every award with the recipient, amount, period and a link to the award record, plus a CSV export. $39/mo.
Sign in or upgradeAwards updated Sat, Oct 10, 2026 · 11:33 PM ET.
This contracting office
8 other open notices from this office · buys mostly Equipment Maintenance & Repair, Supplies & Equipment, Real Estate & Facilities
Similar open RFPs
same PSC J065Listing collected from SAM.gov. Always confirm requirements in the original solicitation before you bid.