Sign inGet alerts
Sources soughtFederal buyer

CRMF SRF Cleanroom and UPW Construction Sources Sought Notification

ENERGY, DEPARTMENT OF, California · ENERGY, DEPARTMENT OF · SLAC Natl Accel Lab -DOE Contractor
Responses dueFri, Oct 235:00 PM PT · California time12 days left
PostedThu, Oct 8No amendments since
Solicitation no.SLAC_DRAFT_RFP_369005_CRMF_Cleanroom_ConstructionSAM.gov
Set-asideNoneOpen to all firms

What the agency is buying

by RFPFinder from the notice and attachments; the solicitation governs

The Department of Energy's SLAC National Accelerator Laboratory seeks general contractors capable of installing a cleanroom and ultra-pure water system in the Cryomodule Repair and Maintenance Facility building in Menlo Park, California. This is a sources sought notice for market research; no award will be made, and a formal best-value solicitation will follow.

Scope

  • Installation of cleanroom inside existing CRMF building at SLAC
  • Optional ultra-pure water system installation and commissioning
Not a solicitation — no awardSubmission: emailDays to respond: 12

How to get the bid documents

  1. Download the 60 stored documents below; 2 more open at the source
  2. Check the submission requirements in the compliance checklist
  3. Submit by email before 5:00 PM PT on Oct 23
Documents · 62 items, 62 filesDownload all (zip) · Pro
  • PDF
    06d5965f3fca4253bc5194987f7a9b96.pdf102 KB · 1 page
  • DOCX
    12b4cb25d7384fd3bc3d0a9563072d1d.docx70 KB
  • DOCX
    15718fd544164024a7b87d27103a6f49.docx67 KB
  • PDF
    1598414ab929480bb7ace31f99fa4fde.pdf14.8 MB · 1366 pages
  • PDF
    2de53a20f61040e18e772d0ef6e6f384.pdf3.7 MB · 93 pages
  • PDF
    2f499421e0d0423c99ce407e9a55d02f.pdf425 KB · 5 pages
  • DOCX
    37039727f7fc4b80898a7af0bd4c0db6.docx76 KB
  • PDF
    3ddaeb658f604200b14ab94218758e50.pdf127 KB · 1 page
  • PDF
    4007192e142b452eb0ae1be431ffda15.pdf687 KB · 2 pages
  • PDF
    4a3f2b561b6644bab7f6b7f8344d62af.pdf137 KB · 5 pages
  • PDF
    57c4569bff9a4ba6844379a791ce9264.pdf264 KB · 7 pages
  • PDF
    650b89bb1fd74a359da0eda74dbb287c.pdf65 KB · 4 pages
  • DOCX
    71309a08a3d74702a163135bc00a64bd.docx897 KB
  • DOCX
    7637274859154c9ebf9344392e5434d1.docx68 KB
  • DOCX
    793f8f182b2649538d28b7f0f60faff3.docx56 KB
  • PDF
    7a14f105ea964ab49bc8f557e8547f74.pdf348 KB · 22 pages
  • DOCX
    804bb8137246417f9c074ff106ca8b27.docx44 KB
  • PDF
    81200282a09d4cee83866c3250f25162.pdf582 KB · 1 page
  • DOC
    downloadToo large, open at source
  • DOCX
    8ef984eb04c246cabed127882b0acc3f.docx63 KB
  • XLSX
    ab91b19b278b48a4b70f4405712bc680.xlsx26 KB
  • DOCX
    aceaf61fd2804fb29aca5d22f07600f2.docx70 KB
  • PDF
    bc7a22e9e95948c6959b8b4a23b997c9.pdf130 KB · 1 page
  • DOCX
    be19e6dbea2049d4a02427a64d5b2d2f.docx60 KB
  • DOCX
    c4a46f5239a04df385b773a032e588d6.docx64 KB
  • DOCX
    c7b5d2049dd54bf7b3227aa9c516dd20.docx50 KB
  • PDF
    d196fd72a820408db049195d5f57f3e3.pdf292 KB · 1 page
  • DOCX
    d1d71ccb538349a1b030a0b3ec0561ec.docx59 KB
  • DOCX
    e420763f640f4e97b26ebf27512d5bdc.docx906 KB
  • DOCX
    f09da0eb6f4441fc9dff2b801ab39db2.docx40 KB
  • DOCX
    fe516656d5c94d37b39d691e58a45a7a.docx63 KB
  • PDF
    B2.03.03_DRAFT-RFP_IFC_Drawings_SLAC_CRMF_Cleanroom.pdf44.6 MBToo large, open at source (44.6 MB)
  • PDF
    B2.03.02_DRAFT-RFP_IFC_Specs_SLAC_CRMF_Cleanroom.pdf14.8 MB · 1366 pages
  • PDF
    B2.07.01_DRAFT-Sec_J_Attachment_01_CWRR_WD.pdf3.7 MB · 93 pages
  • DOCX
    B2.03.04_DRAFT-RFP_Acceptance_Criteria_List_CRMF-1.4-PP-319.docx906 KB
  • DOCX
    B2.03.01_DRAFT-RFP_SOW_CRMF-1.4-SW-224.docx897 KB
  • PDF
    B2.07.04_DRAFT-Sec_J_Attachment_04_SF1413.pdf687 KB · 2 pages
  • PDF
    B2.07.08_DRAFT-Sec_J_Attachment_08_NTP_Checklist_061424.pdf582 KB · 1 page
  • PDF
    B2.07.05_DRAFT-Sec_J_Attachment_05_SQF.pdf425 KB · 5 pages
  • PDF
    B2.07.12_DRAFT-Sec_J_Attachment_12_SBSP_100726.pdf264 KB · 7 pages
  • PDF
    B2.07.03_DRAFT-Sec_J_Attachment_03_IIPP_Form.pdf292 KB · 1 page
  • PDF
    B2.05.01_Fixed_Price_Construction_March_2024.pdf348 KB · 22 pages
  • PDF
    B2.07.02_DRAFT-Sec_J_Attachment_02_Work_Classification.pdf137 KB · 5 pages
  • PDF
    B2.07.10_DRAFT-Sec_J_Attachment_10_LCPTracker_AP_091426.pdf130 KB · 1 page
  • PDF
    B2.07.09_DRAFT-Sec_J_Attachment_09_LCPTracker_NP_091426.pdf127 KB · 1 page
  • PDF
    B2.07.11_DRAFT-Sec_J_Attachment_11_LCPTracker_NC_091426.pdf102 KB · 1 page
  • DOCX
    B2.07.07_DRAFT-Sec_J_Attachment_07_Final_Release.docx56 KB
  • DOCX
    B2.07.06_DRAFT-Sec_J_Attachment_06_Final_Inspection_Report.docx60 KB
  • DOCX
    B2.09.3_DRAFT-RFP_Sec_L-Attachment_C_Past_Performance_Questionnaire_Draft.docx59 KB
  • DOCX
    B2.08.00_DRAFT-RFP_Section_K_(Rep and Certs).docx63 KB
  • DOCX
    B2.09.00_DRAFT-RFP_Sec_L_Instructions_to_Offerors_RFP_369905.docx50 KB
  • DOCX
    B2.05.00_DRAFT-RFP_Section_G_(General_TsCs).docx70 KB
  • DOCX
    B2.07.00_DRAFT-RFP_Section_J_(List of Attachments).docx70 KB
  • DOCX
    B2.06.00_DRAFT-RFP_Section_H_(Special_TsCs).docx67 KB
  • DOCX
    B2.04.00_DRAFT-RFP_Section_F_(Deliveries Performance).docx63 KB
  • DOCX
    B2.10.00_DRAFT-RFP_Sec_M_Evaluation_Criteria_RFP_369905.docx44 KB
  • DOCX
    B2.03.00_DRAFT-RFP_Section_C_(Specifications_SOW).docx64 KB
  • DOCX
    B2.09.01_DRAFT-Sec_L_Attachment_A_SLAC_Question-Clarifications_&_Answer_Log_(RFI).docx40 KB
  • DOCX
    B2.02.00_DRAFT_RFP_Section_B_(Supplies or Services and Price_Costs).docx68 KB
  • PDF
    B2.08.01_DRAFT_RFP_Reps_and_Certs_Supplement.pdf65 KB · 4 pages
  • XLSX
    B2.09.02_DRAFT-Sec_L_Attachment_B_CRMF_Cleanroom_Bid_Breakdown_Draft.xlsx26 KB
  • DOCX
    B2.01.00_DRAFT_RFP_Section_A_(Subcontract_Form).docx76 KB
Open the original listing on SAM.gov

Details

Place of performance
Menlo Park, California
Buyer type
Federal
Notice type
Sources Sought
Solicitation no.
SLAC_DRAFT_RFP_369005_CRMF_Cleanroom_Construction
Evaluation
n/a, market research from notice
Local presence
Not required
Amendments
None since Oct 8
Contact
Jennifer Jamison
Office
SLAC Natl Accel Lab -DOE Contractor
Email
jjamison@slac.stanford.edu

Not stated in the notice: estimated value, contract type, period of performance. Check the bid documents.

Contact details from the source notice. Contact the buyer only about this solicitation.

Key dates

Thu, Oct 8Posted
Not statedQuestions due
Fri, Oct 23 · 5:00 PM PTResponses due · 12 days left Under 14 days

Change log

verified Sat, Oct 10 · 9:30 PM PT

No amendments since posting on Thu, Oct 8; verified Sat, Oct 10 · 9:30 PM PT.

Report a problem

Notice as published

CRMF SRF Cleanroom and UPW Construction Sources Sought Notification

This Draft Request for Proposal (RFP) is a Sources Sought Notice to identify General Contractors (GC) who are capable of completing the planned construction of the Cryomodule Repair and Maintenance Facility (CRMF) Cleanroom and Ultra-Pure Water (UPW) System to support the future repairs to the LCLS-II and LCLS-II-HE cryomodules. This is not a solicitation for proposal, and no award will be made from this Notice. SLAC intends to issue a formal solicitation later based on responses from this Source Sought Notice.

The site for the Cleanroom install will be inside the new CRMF building and is located North of the existing Linac Sector 11, along the North Access Road, adjacent the Sector 10 Adit Road located at the SLAC National Accelerator Laboratory, 2575 Sand Hill Rd, Menlo Park, CA 94025. This project is directly funded by the DOE's Office of Science. The DRAFT RFP package attached consists of construction documents outlining the administrative and technical specifications and drawings pending approval by SLAC's Building Inspection Office (BIO).

The final documents will be used by construction subcontractors to assist in preparing a Firm Fixed Price Proposal. PLANNED SCOPE AND DESCRIPTION OF SERVICES Base Scope (Installation of Cleanroom) The project scope includes installation of a new clean room inside an existing building, known as the Cryomodule Repair and Maintenance Facility (CRMF) building. To accomplish this task, the following specific scope elements must be completed, with all deliverable items meeting requirements as defined in the SOW.

The Subcontractor is to fabricate the cleanroom per the SLAC approved design package generated by an A&E firm. The design package and Building Inspection Office (BIO) stamped print package will be supplied to the awarded Subcontractor. Option 01 Scope (UPW System) The project optional scope includes installation of a new ultra-pure water (UPW) system next to the cleanroom inside the CRMF building.

SLAC National Accelerator Laboratory is seeking to award a fixed-price, turn-key construction subcontract to an experienced and highly qualified and skilled GC, to install the new Cleanroom inside the existing building, known as the Cryomodule Repair and Maintenance Facility (CRMF). The GC is required to install the new Cleanroom as detailed within the Statement of Work, Specifications, and Drawings. The GC is required to adhere to the project schedule, as outlined within the Statement of Work (SOW), while working in conjunction with SLAC to deliver the utmost safety, quality, and meet or surpass the administrative and technical requirements detailed in the Statement of Work, Specifications, and Drawings.

A turn-key Fixed Price construction subcontract will be awarded to the GC who provides the best value to SLAC based on the evaluation criteria. The GC will finalize construction by performing the testing and commissioning of all new systems working with CRMF and SLAC Operations teams for a completed facility. DRAFT REQUEST FOR PROPOSAL SLAC will use a single step Best Value Trade Off selection method to identify the GC who provides the best value to SLAC based on the evaluation criteria.

The Draft RFP and relevant draft references are provided to present the general scope and acquisition method for the project. The draft documents provided are subject to change and should not be construed as a solicitation. This Sources Sought Notice is NOT A SOLICITATION but instead is to identify interested vendors for the upcoming formal solicitation release.

SOURCES SOUGHT RESPONSE Interested GCs with the skills, capability, workload capability, and ability to obtain bonding to complete the planned project scope are invited to submit a written response to this Sources Sought Notice. Please provide the following information: Company Name Name, telephone number, and email addresses of your company point of contact(s) who have the authority and knowledge to clarify responses. A statement of your company's interest in receiving the formal solicitation notice and in submitting a responsive statement of qualifications.

Please provide your response to Jennifer Jamison at: [email on the source notice] by 5:00 pm PST on Friday, October 23, 2026.

SOURCES SOUGHT DISCLAIMER: Please note that any responses to this Sources Sought posting is purely on a voluntary basis. SLAC is not requesting a proposal, any pricing, or any other information that could be considered confidential or proprietary to be submitted in response to this posting or any part of this posting. Any submissions that contain pricing, proprietary information, or confidential information will be discarded by SLAC.

Award history

USAspending.gov, last 36 months

Award history for this agency is not loaded yet.

Awards for this key have not been synced yet.

This contracting office

1 other open notice from this office · buys mostly Supplies & Equipment, Other

Listing collected from SAM.gov. Always confirm requirements in the original solicitation before you bid.

Alert meView on SAM.gov