What the agency is buying
by RFPFinder from the notice and attachments; the solicitation governsThe Department of Defense is seeking proposals for the repair and renovation of Bachelor Enlisted Quarters Building 3606 at JEB Little Creek-Fort Story, Virginia Beach, VA. This will be an unrestricted procurement with full and open competition, evaluated by an unknown method under an unknown contract type.
Scope
- Repair and upgrade Bachelor Enlisted Quarters (BEQ) Building 3606 to Q1 rating.
- Replace major building systems, reconfigure room layouts, and update to current codes.
How to get the bid documents
- Download the 3 stored documents below; 1 more open at the source
- Check the submission requirements in the compliance checklist
- Submit as the notice directs before the deadline
Details
- Place of performance
- NORFOLK, Virginia
- Buyer type
- Federal
- Notice type
- Presolicitation
- Solicitation no.
- N40085-17-R-0309
- Category
- Construction
- Size standard
- $45M revenue SBA table, NAICS 236220
- Delivery location
- JEB Little Creek-Fort Story, Virginia Beach, VA from notice
- Period of performance
- 572 calendar days after award from notice
- Evaluation
- Sealed bid, price only (FAR 14) from notice
- Estimated value
- $100M from notice
- Local presence
- Required
- Amendments
- 14, last May 2, 2017
- Contact
- Kate Dinneen 757-341-1031 Katherine.dinneen@navy.mil
- Office
- DEPT OF THE NAVY · NAVFACSYSCOM MID-ATLANTIC
Not stated in the notice: contract type. Check the bid documents.
Contact details from the source notice. Contact the buyer only about this solicitation.
Key dates
- Amendment 1
- Mon, Dec 12, 2016
- Amendment 2
- Tue, Dec 13, 2016
- Amendment 3
- Tue, Dec 27, 2016
- Amendment 4
- Tue, Jan 17, 2017
- Amendment 5
- Tue, Mar 21, 2017
- Amendment 6
- Tue, Mar 28, 2017
- Amendment 7
- Wed, Apr 5, 2017
- Amendment 8
- Thu, Apr 13, 2017
- Amendment 9
- Mon, Apr 17, 2017
- Amendment 10
- Thu, Apr 20, 2017
- Amendment 11
- Tue, Apr 25, 2017
- Amendment 12
- Tue, Apr 25, 2017
- Amendment 13
- Wed, Apr 26, 2017
- Amendment 14
- Tue, May 2, 2017
Change log
verified Sat, Oct 10 · 12:30 AM ET- Posted · PresolicitationFri, Dec 9, 2016 · 6:07 AM ET
- Amendment · New version of the notice posted at the sourceMon, Dec 12, 2016 · 4:33 AM ET
- Amendment · New version of the notice posted at the sourceTue, Dec 13, 2016 · 5:28 AM ET
- Amendment · New version of the notice posted at the sourceTue, Dec 27, 2016 · 7:50 AM ET
- Amendment · New version of the notice posted at the sourceTue, Jan 17, 2017 · 4:58 AM ET
- Amendment · New version of the notice posted at the sourceTue, Mar 21, 2017 · 11:12 AM ET
- Amendment · New version of the notice posted at the sourceTue, Mar 28, 2017 · 10:04 AM ET
- Amendment · New version of the notice posted at the sourceWed, Apr 5, 2017 · 4:47 AM ET
- Amendment · New version of the notice posted at the sourceThu, Apr 13, 2017 · 6:55 AM ET
- Amendment · New version of the notice posted at the sourceMon, Apr 17, 2017 · 8:18 AM ET
- Amendment · New version of the notice posted at the sourceThu, Apr 20, 2017 · 11:59 AM ET
- Amendment · New version of the notice posted at the sourceTue, Apr 25, 2017 · 4:58 AM ET
- Amendment · New version of the notice posted at the sourceTue, Apr 25, 2017 · 6:11 AM ET
- Amendment · New version of the notice posted at the sourceWed, Apr 26, 2017 · 1:27 PM ET
- Amendment · New version of the notice posted at the sourceTue, May 2, 2017 · 12:03 PM ET
Report a problem
Notice as published
Z--RM12-2050, Repair and Renovate UPH-BEQ Building 3606, JEB Little Creek-Fort Story, Virginia Beach, VA.
This is neither a request for quote or proposal nor an invitation for bid. The intent of this pre-solicitation synopsis is to inform potential offerors of this requirement. The Request for Proposal (RFP) will be issued by NAVFAC Mid-Atlantic Hampton Roads IPT on or about 27 December 2016.
The solicitation number will be N40085-17-R-0309 on the Navy Electronic Commerce Online website (NECO) at https://www.neco.navy.mil/index.aspx A Vendor User Guide is available for download at the site as well as the NECO Help Desk contact phone number for any issues/questions related to the website. Ensure that you register with the site so you will receive emails applicable to this solicitation in the event of any amendments and/or any changes regarding this solicitation and/or solicitation of interest.
Primary POC: Kate Dinneen, Phone: (757) 341-1031, Email: [email on the source notice] A sources sought notice was posted on 8 November 2016 under synopsis N40085-17-R-0309 to determine availability and capability of small businesses to perform the requirement. Based on market research results, the procurement will be solicited on an unrestricted basis with full and open competition. NAVFAC Mid-Atlantic’s Office of Small Business Programs concurs with the determination to solicit as an unrestricted procurement.
Project Description: This project will repair and upgrade Bachelor Enlisted Quarters (BEQ) Building 3606 by eliminating all Q4 Condition and/or Configuration ratings to bring these facilities up to a Q1 rating to comply with the Defense Planning Guidance. All major building systems are substandard and need replacement. Facility repairs will meet current code requirements and correct existing deficiencies.
Room layouts will be reconfigured to provide two separate baths and service areas (2+0 concept) in lieu of one shared bath for two rooms; remove and replace two closets to fit the reconfigured space. This project will inspect, replace or repair the existing sanitary waste drain lines in the laundry room in building 3606A. All existing sanitary sewer piping in 3606 will be replaced.
Electrical breaker panels will be replaced as required to handle the electrical load. The existing 3606 building ventilation system and ducts will be replaced. The facility will be brought up to all Antiterrorism /Force Protection (ATFP) standards in accordance with Unified Facilities Criteria (UFC) 4-010-01 including progressive collapse.
The exterior walls of the buildings will be power washed and a mold growth inhibitor paint applied. All emergency lighting and exit signs will be replaced with energy efficient stainless steel fixtures with a protective metal cage placed around them to prevent vandalism. Additional video security cameras will be provided to for security coverage to all blind areas and the existing security monitoring system will be upgraded as required to handle the cameras.
The existing trash dumpster enclosures will be replaced with higher side walls and lockable gates. The deteriorated elevators will be replaced and security cameras will be provided. The current fire alarm and detection system does not meet current standards and must be replaced to bring these buildings in compliance with current life safety codes and UFC-3-600-01.
Properly sized natural gas potable hot water boilers will be provided in 3606B to supply the domestic hot water requirements of 3606 and 3606A. Landscaping site improvements will be incorporated in this project. The project replaces the existing 2-pipe heating and cooling system in buildings 3606 and 3606A and provides temporary heating and cooling for building 3609 until a project for building 3609 is programmed.
The heating, ventilation, and air conditioning (HVAC) system and direct digital controls (DDC) used should be the most energy efficient system possible, but natural gas was used for planning and estimating purposes. Alternative types of energy efficient HVAC systems will be taken into consideration with the goal to meet the reduced energy consumption mandates. Building 3606 is a five-story, 91,000 SF BEQ built in 1989 and building 3606A is a 7,680 SF BEQ support building built in 1989.
The scope of work includes replacing the mechanical system in building 3606B for buildings 3606 and 3606A. These buildings are constructed so that the mechanical systems are interconnected. This project will remove this interconnection so as to provide each building with an independent mechanical system.
This will allow isolation of each in case of an outage or necessary repairs. The work also includes all incidental work to make the HVAC system functional. All facilities will include cybersecurity commissioning for infrastructure systems such as Direct Digital (DDC) controls, fire alarm and detection and security monitoring systems.
This project will install a complete and useable fire sprinkler system and a roof replacement in building 3606B. The estimated construction cost is between $25,000,000 and $100,000,000. The anticipated award of this contract is June 2017.
The completion time for this contract is 572 calendar days after award. The specifications for this project will be posted with the solicitation and are not available at this time. The North American Industry Classification System (NAICS) Code for this project is 236220, Commercial and Institutional Building Construction, with a small business size standard of $36.5 million.
What this office paid before
USAspending.gov, last 36 months21 awards matched · tier 1: this contracting office (N40085) + NAICS 236220. Most recent:
Pro shows every award with the recipient, amount, period and a link to the award record, plus a CSV export. $39/mo.
Sign in or upgradeAwards updated Sat, Oct 10, 2026 · 12:51 AM ET.
This contracting office
33 other open notices from this office · buys mostly Construction, Other, Real Estate & Facilities
Related notices
Similar open RFPs
same NAICS 236220Listing collected from SAM.gov. Always confirm requirements in the original solicitation before you bid.