Sign inGet alerts

Closed Mon, Oct 5. Responses were due Mon, Sep 21 · 12:00 PM ET. This notice is kept for reference and no longer takes responses.

Request for proposalsFederal buyerSB

Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer

COMMERCE, DEPARTMENT OF, Maryland · NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY · DEPT OF COMMERCE NIST
Unverified · check sourceAmended Sep 17
Responses dueMon, Sep 2112:00 PM ET · Maryland timeClosed
PostedTue, Sep 151 amendment, last Sep 17
Solicitation no.1333ND26QNB640601SAM.gov
Set-asideSBOnly firms holding this status can compete

What the agency is buying

from the notice as published

***Amendment 0001**** Amendment 0001 provides resposnes to questions received in response to the solicitation. Q.1. I am reviewing Notice ID 1333ND26QNB640601 and would appreciate some clarification regarding the analytical requirements. Would you be able to share the analytes of interest, the required detection limits, and the expected concentration ranges for the system? A.1. This analyzer…

Small business set-aside

How to get the bid documents

Attachment list not pulled yet; check the source notice.

Open the original listing on SAM.gov

Details

Place of performance
Gaithersburg, Maryland
Buyer type
Federal
Notice type
Solicitation
Solicitation no.
1333ND26QNB640601
NAICS
NAICS 334516 (Analytical Laboratory Instrument Manufacturing): 28 open RFPs
Size standard
1,000 employees SBA table, NAICS 334516
PSC
PSC 6630 (CHEMICAL ANALYSIS INSTRUMENTS): 3 open RFPs
Amendments
1, last Sep 17
Contact
Rudolph Spencer
Office
NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY · DEPT OF COMMERCE NIST
Email
rudolph.spencer@nist.gov

Not stated in the notice: estimated value, contract type, period of performance, evaluation criteria, local-presence rule, quantity, FOB terms. Check the bid documents.

Contact details from the source notice. Contact the buyer only about this solicitation.

Key dates

Tue, Sep 15Posted
Not statedQuestions due
Mon, Sep 21 · 12:00 PM ETResponses due · closed
Amendment 1
Thu, Sep 17
Closed
Mon, Oct 5

Change log

verified Tue, Oct 6 · 12:30 AM ET
  1. Posted · SolicitationTue, Sep 15 · 5:03 AM ET
  2. Amendment · New version of the notice posted at the sourceThu, Sep 17 · 9:27 AM ET
  3. ClosedMon, Oct 5 · 6:35 AM ET

Change log starts Oct 5, 2026 (tracking began); earlier amendments at SAM.gov are being pulled in.

Report a problem

Notice as published

Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer

***Amendment 0001**** Amendment 0001 provides resposnes to questions received in response to the solicitation. Q.1. I am reviewing Notice ID 1333ND26QNB640601 and would appreciate some clarification regarding the analytical requirements.

Would you be able to share the analytes of interest, the required detection limits, and the expected concentration ranges for the system? A.1. This analyzer will be used for the analysis of binary gas mixtures in nitrogen or air balance gases.

The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector. This analyzer will also be used for analyses of ambient level CO in air mixtures, ranging from (40 – 200) ppb. Q.2.

What types of samples will be tested? A.2. This analyzer will be used for analyses of high pressure gas mixtures in nitrogen or air balance gases.

Q.3. What specific substances or compounds need to be detected or analyzed in these samples? If available, please also share any specific testing standards or requirements.

With this information, we can better understand your application and recommend a suitable instrument configuration and quotation accordingly. A.3. As stated above, this analyzer will be used for the analysis of high pressure gas mixtures delivered at or below 25 psig.

The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector. For improved precision, temperature ramping and stable detector response are required to achieve baseline resolution between components in air balance gas. In all cases the repeatability should be at or below 0.2 % relative area counts.

Q.4. Regarding your software requirements, you cite Visual Basic Version 6.0. Would that software be able to generate an XML file to communicate with our software (CompassCDS)?

A.4. The visual basic software was developed to support communication between the GC software and a 12-port dead-end VICI sampling valve. The software can retrieve data from a txt file generated by the GC software and output the data to excel.

There is not an extension to the solicitation as a result of this amendment. The question period for this soliciation will close today, September 17,2026, at 4:00 PM ET. End of Amendment 0001 ******** See attached.

Similar federal awards · PSC 6630

USAspending.gov, last 36 months

25 awards matched · tier 3: PSC 6630 at any agency; nothing from this office or agency. Most recent:

  • Oct 6ABBOTT LABORATORIES INC.COST PER TEST36C24827N0090 · DELIVERY ORDER · Department of Veterans Affairs · ends Sep 29, 2027$334K
Pro

Pro shows every award with the recipient, amount, period and a link to the award record, plus a CSV export. $39/mo.

Sign in or upgrade

Awards for this key have not been synced yet.

This contracting office

8 other open notices from this office · buys mostly Other

Similar open RFPs

same PSC 6630

Listing collected from SAM.gov. Always confirm requirements in the original solicitation before you bid.

Alert meView on SAM.gov