What the agency is buying
by RFPFinder from the notice; the solicitation governsThe EPA intends to award a fixed price contract to Agilent Technologies, Inc. for an Agilent 8890 GC System.
Scope
- Agilent 8890 GC System Custom with dual ECD detectors
- GC must contain two inlets that are electronic pneumatic controlled (EPC) with standard and inert flow path with split/splitless capillary inlet (S/SL)
How to get the bid documents
- Open the notice on SAM.gov
- Download the 1 attachment listed below from the source
- Submit by email before 4:30 PM ET on Apr 26, 2027
Details
- Place of performance
- ATLANTA, Georgia
- Buyer type
- Federal
- Notice type
- Special Notice
- Solicitation no.
- 68HE04-26-Q-0008
- Size standard
- $41M revenue SBA table, NAICS 221310
- Contract type
- sole source from notice
- Evaluation
- Best value tradeoff (FAR 15) from notice
- Estimated value
- $350K from notice
- Approved sources
- Agilent Technologies, Inc. from notice
- Local presence
- Not required
- Amendments
- None since Mar 26
- Contact
- Wallace, Megan
- Office
- REGION 4 CONTRACTING OFFICE
- Phone
- (513) 569-7927
Not stated in the notice: period of performance, quantity, FOB terms. Check the bid documents.
Contact details from the source notice. Contact the buyer only about this solicitation.
Key dates
Change log
verified Wed, Oct 7 · 12:30 AM ETNo amendments since posting on Thu, Mar 26, 2026; verified Wed, Oct 7 · 12:30 AM ET.
Change log starts Oct 5, 2026 (tracking began); earlier amendments at SAM.gov are being pulled in.
Report a problem
Notice as published
66--Single Purchase of an Agilent 8890 GC System Custom with dual ECD detectors
This is a notice of intent, not a request for a quotation. A solicitation document will not be issued, and quotations will not be requested. The Environmental Protection Agency (EPA) intends to award a fixed price contract on a sole source basis to Agilent Technologies, Inc. for the purchase, delivery and installation of an Agilent 8890 GC System with dual electron capture detectors and dual split/splitless inlets.
The requirement is to perform PCB and pesticide analysis on soil and water samples using multiple EPA methods including 8081B and 8082A. The autosampler must contain 150 sample positions and be able to deliver samples and standards from the sample vials into the GC inlet. The GC must contain two inlets that are electronic pneumatic controlled (EPC) with standard and inert flow path with split/splitless capillary inlet (S/SL).
Agilent Technologies, Inc. is the only vendor that can supply the requisite equipment supporting efficiency and transferability of use with the supporting equipment components that result in the best value to the government. The continued use of products from this manufacturer allows for ease of continued operation, as all current analysts have been thoroughly trained in the use and maintenance of Agilent GCs. Continuity of instrumentation will also allow for easier and quicker training of new employees as well as cross-training existing employees.
The new GC-ECD manufactured by Agilent Technologies, Inc., are compatible with the laboratory's current quality system, operational equipment and existing sample analysis policies and procedures. As a result, procurement from the vendor represents the best value to the government and provides the only source of supply. This purchase will be made utilizing Simplified Acquisition Procedures in accordance with Federal Regulation (FAR) Part 13.106-1(b)(1) for purchases not exceeding the simplified acquisition threshold of $350,000.00.
Pursuant to the authority granted by 41 U.S.C.253(c) (1), only one responsible source and no other supplies or services will satisfy agency requirements as implemented by FAR 6.302-1. The U.S. Environmental Protection Agency (EPA), Office of Mission Support's Acquisition and Grants Management's Branch intends to issue a task order to Agilent Technologies, Inc. for the purchase, delivery and installation of an Agilent 8890 GC System.
The sole source nature of this requirement is based on the determination Agilent Technologies, Inc is the only organization that can support this requirement. Market research reflects that Agilent Technologies, Inc. is the only source for the Agilent 8890 GC System. No other source meets the requirement.
The determination not to compete this proposed contract action is solely within the discretion of the Government. Information received will normally be considered for the purposes of determining whether to conduct a competitive procurement. The Government will not be responsible for any costs incurred by responding to this notice.
Questions or comments to this Notice of Intent should be directed to the Contracting Officer, Megan Wallace, [email on the source notice] and/or the Contract Specialist, Femi Obadina, [email on the source notice]. Please indicate in the subject of your email: Notice of Intent Submission: Requisition PR-R4-26-00172.
Similar Environmental Protection Agency awards · PSC 6630
USAspending.gov, last 36 months25 awards matched · tier 2: Environmental Protection Agency + PSC 6630; nothing from this office. Most recent:
Pro shows every award with the recipient, amount, period and a link to the award record, plus a CSV export. $39/mo.
Sign in or upgradeAwards updated Tue, Oct 6, 2026 · 7:18 AM ET.
Similar open RFPs
same PSC 6630Listing collected from SAM.gov. Always confirm requirements in the original solicitation before you bid.