What the agency is buying
by RFPFinder from the notice and attachments; the solicitation governsThe 628th Contracting Squadron at Joint Base Charleston, SC is seeking capabilities packages for the renovation of the Naval Reserve Building 3370. The project includes replacing the HVAC equipment to eliminate mold growth and incidental related work.
Scope
- Renovation of the Naval Reserve Building 3370 at Joint Base Charleston, South Carolina.
- Replace the HVAC equipment to eliminate mold growth inside the facility.
How to get the bid documents
- Download the 1 document below (no portal account needed)
- Check the submission requirements in the compliance checklist
- Submit as the notice directs before 12:00 PM ET on Apr 1, 2029
Details
- Place of performance
- Charleston AFB, South Carolina
- Buyer type
- Federal
- Notice type
- Sources Sought
- Solicitation no.
- DKGV-1137999
- Category
- Construction · beta
- Size standard
- $45M revenue SBA table, NAICS 236220
- Quantity
- 250 each from notice
- Delivery location
- Joint Base Charleston, South Carolina from notice
- Contract type
- IDIQ from notice
- Evaluation
- n/a, market research from notice
- Estimated value
- $3.0M from notice
- Local presence
- Not required
- Amendments
- 2, last Oct 7
- Contact
- Byron Faison
- Office
- DEPT OF THE AIR FORCE · FA4418 628 CONS PK
- Phone
- 8439635167
Not stated in the notice: period of performance. Check the bid documents.
Contact details from the source notice. Contact the buyer only about this solicitation.
Key dates
- Amendment 1
- Wed, Mar 18, 2026
- Amendment 2
- Wed, Oct 7, 2026 · The government procurement notice has been updated to include additional project details, such as the need for cybersecurity, HAZMAT survey, and plumbing sewer line repair, and to clarify the project.
Change log
verified Mon, Oct 12 · 12:30 AM ET- Posted · Sources SoughtTue, Mar 17 · 11:02 AM ET
- Amendment · New version of the notice posted at the sourceWed, Mar 18 · 2:43 AM ET
- Updated · description text changedWed, Oct 7 · 12:34 AM ET
- Amendment · The government procurement notice has been updated to include additional project details, such as the need for cybersecurity, HAZMAT survey, and plumbing sewer line repair, and to clarify the project.Wed, Oct 7 · 12:34 AM ET
- Updated · description text changedThu, Oct 8 · 12:32 AM ET
- Updated · description text changedThu, Oct 8 · 12:32 AM ET
- Updated · description text changedFri, Oct 9 · 12:33 AM ET
- Updated · description text changedFri, Oct 9 · 12:33 AM ET
- Updated · description text changedSat, Oct 10 · 12:33 AM ET
- Updated · description text changedSat, Oct 10 · 12:33 AM ET
- Updated · description text changedSun, Oct 11 · 12:32 AM ET
- Updated · description text changedMon, Oct 12 · 12:33 AM ET
Report a problem
Notice as published
Repair Natural Resources Facility B3370
The 628th Contracting Squadron at Joint Base Charleston (JBC), SC is seeking capabilities packages from potential sources for planning purposes for the Repair Natural Resources Facility B3370 at Joint Base Charleston, South Carolina. This project includes the renovation of the Naval Reserve Building 3370 that is used for reserve training 1-2 weekends per month with approximately 250 occupants per weekend. Daily occupancy is about 25 people on a normal usage, and the weekends have high occupancy.
The project scope is to replace the HVAC equipment in attempts to eliminate the recent mold growth inside the facility and incidental related work. The humid air has caused the need for temporary de-humidifiers and mold cleanup within the facility. The building currently has numerous HVAC roof top units (RTUs), and the climate control is not working to reduce the high humidity inside the building.
A new HVAC system will be designed and any mold or water damaged areas removed, and finishes restored, such as re-painting or replacing ceiling tiles. Cybersecurity is also required for this project Renovation. The renovation shall include providing new HVAC units on the roof and providing any electrical equipment needed to support the new HVAC system, as well as providing duct smoke detectors.
A HAZMAT survey was performed to determine the extent of mold that may need to be abated during demolition and refinishing. A plumbing sewer line needs repair at the latrines, to replace it with positive drainage to the existing sewer pump. Dollar magnitude of this requirement is between $1,000,000.00 and $5,000,000.00.
The NAICS Code assigned to this acquisition is 2362200 Commercial and Institutional Building Construction with a Size Standard of $45,000,000.00
What this office paid before
USAspending.gov, last 36 months22 awards matched · tier 1: this contracting office (FA4418) + PSC Z2AA. Most recent:
Pro shows every award with the recipient, amount, period and a link to the award record, plus a CSV export. $39/mo.
Sign in or upgradeAwards updated Sat, Oct 10, 2026 · 12:50 AM ET.
This contracting office
No other open notices from this office · buys mostly Construction
Similar open RFPs