What the agency is buying
by RFPFinder from the notice and attachments; the solicitation governsThe Department of Defense seeks cable assemblies for shipboard use via RFQ N00104-23-Q-FA30. Vendors must submit quotes by 29 December 2023 with certification data 20 days prior to delivery; first article approval is required.
Scope
- Cable Assembly per NAVSEA Drawing 5486639 and 5486641, Dry Deck Shelter Procurement Specification S-5343934-2
- Quantity 6 each, FOB destination, 300-day delivery schedule with quality conformance testing
How to get the bid documents
- Download the 4 stored documents below; 4 more open at the source
- Check the submission requirements in the compliance checklist
- Submit as the notice directs before 3:30 PM ET on Nov 25
Details
- Place of performance
- MECHANICSBURG, Pennsylvania
- Buyer type
- Federal
- Notice type
- Solicitation
- Solicitation no.
- N00104-23-Q-FA30
- Category
- Supplies & Equipment · beta
- Size standard
- 750 employees SBA table, NAICS 333613
- Quantity
- 6 each from attachment p.2
- Delivery location
- NAVSUP Weapon Systems Support, Mechanicsburg, PA from attachment p.2
- FOB
- Destination from attachment p.1
- Period of performance
- 300-day delivery schedule with certification data submission 20 days prior to delivery from attachment p.2
- NSN
- 3040-01-661-8530 from attachment p.2
- Part number
- 1400400-0600 from attachment p.4
- Local presence
- Not required
- Amendments
- 1, last Oct 21
- Contact
- Facsimile: 7176054236
- Office
- DEPT OF THE NAVY · NAVSUP WEAPON SYSTEMS SUPPORT MECH
Not stated in the notice: estimated value. Check the bid documents.
Contact details from the source notice. Contact the buyer only about this solicitation.
Line items
from attachment p.1| CLIN | Item | Qty | Unit | Option qty |
|---|---|---|---|---|
| 5450 | CARLISLE PIKE | 300 | DAYS | - |
| 0001AA | N00104-22-X-5866 N50286 | 6 | EA | - |
Key dates
- Amendment 06
- Wed, Oct 21, 2026 ·
Change log
verified Fri, Oct 23 · 12:30 AM ET- Posted · SolicitationWed, Nov 16, 2022 · 3:57 AM ET
- Amendment · Amendment 06Wed, Oct 21, 2026 · 4:46 AM ET
Report a problem
Notice as published
30--CABLE ASSY
49998|3383247 DRAWING DATA=
49998|1542116 DRAWING DATA=
| |080101|A|
DOCUMENT REF DATA=MIL-STD-792
|F |060519|A|
DOCUMENT REF DATA=ISO_9001
| |081115|A|
DOCUMENT REF DATA=ISO10012
| |030415|A|
DOCUMENT REF DATA=ISO/IEC 17025
| |050515|A|
DOCUMENT REF DATA=MIL-I-45208
|A |810724|A|1
DOCUMENT REF DATA=MIL-STD-45662
|A |880801|A|
DOCUMENT REF DATA=ANSI/NCSL Z540.3
| |130326|A|
DOCUMENT REF DATA=S9074-AQ-GIB-010/248
|1 |191112|A|
DOCUMENT REF DATA=SS800-AG-MAN-010/P-9290
|A |200424|A| |42| DOCUMENT REF DATA=S9074-AR-GIB-010A/278 (CHG A)
| |130214|A|
DOCUMENT REF DATA=S9320-AM-PRO-020/MLDG
|2 |990801|A|
- REQUIREMENTS 3.1 ;The Cable Assembly must be manufactured in accordance with NAVSEA Drawing 5486639 Item 193, NAVSEA Drawing 5486641 Part Number K-HNG5700, Dry Deck Shelter Procurement Specification S-5343934-2 Part Number 1400400-0600, CSD313, CSD317, and CSD321 except as amplified or modified herein.; 3.2 ;Drawing 7329665 does not apply.; 3.3 The cable assembly must be wired and molded in accordance with volume II of NAVSEA S9320-AM-PRO-020/MLDG by an approved vendor listed in CSD023 of the ECDS (Electronic Contractor Data Submission) system at: https://register.nslc.navy.mil/ 3.3.1 The approved vendor utilized for this contract, if other than the prime manufacturer, must be identified on the Special Emphasis C of C. 3.4 Each cable assembly must be subjected to the Quality Conformance tests of specification S-5343934-2 Tables 2 and 3; except that Table 3 of S-5343934-2 must be modified by CSD031 of the Contract Support Library.
- Examination of Product IAW paragraph 3.4 and tested to paragraph 4.6 2.
Dielectric Withstanding Voltage IAW paragraph 3.6.1 and tested to paragraph 4.7.1 3. Continuity IAW paragraph 3.6.2 and tested to paragraph 4.7.2
- Insulation Resistance IAW paragraph 3.6.3 and tested to paragraph 4.7.3 5.
Hydrostatic Pressure IAW paragraph 3.6.4 and tested to paragraph 4.7.4 6. Post-Test Examination of Product IAW paragraph 4.6.1 3.4.1 Each conformance test must be listed separately on the Navy Special Emphasis Program (NSEP) Certificate of Compliance (C of C) as being performed and found acceptable.
3.5 The pressure tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure tolerances are not provided by drawings, specifications or specified elsewhere in this contract, the following must be used: For pressure tests below 100 PSIG, the pressure tolerance must be +1 PSIG/-0PSIG. For pressure tests at or above 100 PSIG up to and including 2500 PSIG, the pressure tolerance must be +2% / -0 PSIG rounded off to the nearest multiple of thesmallest graduation on an analog test pressure gauge, not to exceed 50 PSIG.
30 minutes / - 0 minutes. above 2500 PSIG, the pressure tolerance must be +2%/-0 PSIG, rounded off to the nearest multiple of the smallest graduation on an analog test pressure gauge, not to exceed 200 PSIG. The pressure test time tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure test time tolerances are not provided by drawings, specifications or specified elsewhere in this contract, the following must be used: For a test duration up to and including 1 hour, the tolerance must be +5 minutes / - 0 minutes.
For a test duration of more than 1 hour up to and including 24 hours, the tolerance must be +30 minutes / - 0 minutes. For a test duration of more than 24 hours, the tolerance must be + 60 minutes/- 0 minutes. 3.6 Contract Support Library - Additional requirements for this item are identified as Contract Support Library Reference Number ;CSD023, CSD031, CSD313, CSD317, and CSD321; in ECDS at https://register.nslc.navy.mil/ 3.7 Welding or Brazing - When welding, brazing, and allied processes are required, as invoked by Section C paragraph 3 requirements, they must be in accordance with S9074-AR-GIB-010A/278, (S9074-AQ-GIB-010/248 for brazing) by personnel and procedures qualified under S9074-AQ-GIB-010/248 for all production and repair welding and brazing.
Procedures and Qualification Data must be submitted for review and approval prior to performing any welding or brazing. 3.8 First Article Approval (Contractor Testing) - First Article Test (FAT) and approval is required. 3.9 Configuration Control - The Contractor must maintain the total equipment baseline configuration.
For items of proprietary design, Contractor drawings showing the latest assembly configuration must be provided to the Government in electronic (C4) format. Definitions are provided elsewhere in the Contract/Purchase Order. 3.9.1 Waivers/Deviations - All waivers and deviations, regardless of significance or classification require review and approval by the Contracting Officer.
Waivers and Deviations must be designated as Critical, Major, or Minor. The Contractor must provide a copy of this request to the QAR. Requests must include the information listed below. a.
A complete description of the contract requirement affected and the nature of the waiver/deviation (non-conformance), including a classification of Critical, Major, or Minor. b. Number of units (and serial/lot numbers) to be delivered in this configuration. c. Any impacts to logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel or impacts to the operational use of the product. d.
Information about remedial action being taken to prevent reoccurrence of the non-conformance. 3.9.2 All requests for Waivers/Deviations on NAVSUP-WSS Contracts must be submitted using the ECDS (Electronic Contractor Data Submission) system at https://register.nslc.navy.mil/ 3.9.3 ECPs - The Government will maintain configuration control and change authority for all modifications or changes affecting form, fit, function, or interface parameters of the Equipment and its sub-assemblies. The Contractor must submit an Engineering Change Proposal (ECP) for any Class I or II changes that impact the Equipment covered by this contract.
ECPs must be prepared in Contractor format, and must include the following information: a. The change priority, change classification (Class I or Class II), and change justification. b. A complete description of the change to be made and the need for that change. c.
A complete listing of other Configuration Items impacted by the proposed change and a description of the impact on those CIs. d. Proposed changes to documents controlled by the Government. e. Proposed serial/lot number effectivities of units to be produced in, or retrofitted to, the proposed configuration. f.
Recommendations about the way a retrofit should be accomplished. g. Impacts to any logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel in support of the product. h. Impacts to the operational use of the product. i.
Complete estimated life-cycle cost impact of the proposed change. j. Milestones relating to the processing and implementation of the engineering change. 3.9.4 A copy of the final waiver/deviation (both approved and disapproved) must be forwarded with the applicable asset(s).
3.10 Certificate of Compliance - (SPECIAL EMPHASIS MATERIAL) The Contractor must prepare and submit a certificate of compliance certifying that the items/components furnished under this contract comply with the requirements of the procurement document, including any/all invoked specifications and drawings. 3.11 Mercury Free - Mercury and mercury containing compounds must not be intentionally added or come in direct contact with hardware or supplies furnished under this contract. Mercury contamination of the material will be cause for rejection. ^ QUALITY ASSURANCE REQUIREMENTS ^ 3.12 Quality System Requirements - The Contractor furnishing items under this contract/purchase order must provide and maintain a quality system in accordance with ISO-9001 as amplified or modified herein, with the calibration system requirements of ISO-10012 or ANSI-Z540.3 with ISO-17025.
A Quality System in accordance with MIL-I-45208, with the calibration system requirements of MIL-STD-45662, is acceptable as an alternate. 3.12.1 The Contractor's quality system and products supplied under the system are subject to evaluation, verification inspection, and acceptance/nonacceptance by the Government representative to determine the system's effectiveness in meeting the quality requirements established in the Contract/Purchase Order. 3.12.2 The Contractor's quality system must be documented and must be available for review by the Contracting Officer or his representative prior to initiation of production and throughout the life of the contract.
The Prime Contractor must, upon notification, make his facilities available for audit by the contracting Officer or his authorized representative. 3.12.3 See CDRL DI-QCIC-81110 (Inspection System Procedures) - All suppliers of Deep Submergence Systems Program (DSSP) material are required to submit a copy of their current documented quality system procedures to the Procurement Contracting Officer (PCO) prior to award of any contract/purchase order. Suppliers that have a copy of their current quality system procedures on file at NAVICP-Mech may request the PCO waive this requirement.
3.12.4 This contract provides for the performance of Government Quality Assurance at source. The place or places of performance may not be changed without the authorization of the Procurement Contracting Officer. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished.
If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately. 3.12.5 Any changes made by the Contractor to a qualified quality system will require concurrence by the Government Quality Assurance Representative prior to adoption.
3.13 Contractor Inspection Requirements - The Contractor must maintain adequate records of all inspections and tests. The records must indicate the nature and number of observations made, the number and type of deficiencies found, the quantities approved and rejected and the nature of corrective action taken as appropriate. 3.13.1 The supplier's gages, measuring and test equipment must be made available for use by the Government representative when required to determine conformance with Contract requirements.
When conditions warrant, the supplier's personnel must be made available for operations of such devices and for verification of their accuracy and condition. 3.13.2 All documents and reference data applicable to this contract must be available for review by the Government representative. Copies of documents required for Government inspection purposes must be furnished in accordance with the instructions provided by the Government representative.
3.14 Subcontractor Inspection Requirements - The Government has the right to inspect at source, any supplies or services that were not manufactured/performed within the contractor's facility. Such inspection can only be requested by or under authorization of the Government representative. Any purchasing documents to a subcontractor must cite the applicable portions of the contractually invoked quality system (e.g. calibration requirements), plus any product requirements that apply to the supplies being purchased.
When the Government elects to perform source inspection at the subcontractor's facility, applicable purchase documents must be annotated with the following statement: "A Government inspection is required prior to shipment from your plant. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office.
In the event that a local Government representative DCMA Office cannot be located, our purchasing agent should be notified immediately." 3.15 Government Furnished Material and/or Equipment (GFM/GFE) - When material or equipment is furnished by the Government, the Contractor must develop documented control procedures that require at least the following: 3.15.1 Visual examination upon receipt to detect damage during transit. 3.15.2 Inspection for completeness and proper type. 3.15.3 Verification of material quality received.
3.15.4 Periodic inspection and precautions to assure adequate storage conditions and to guard against damage from handling and deterioration during storage. 3.15.5 Functional testing, either prior to or after installation, or both, as required by the Contract to determine satisfactory operation. 3.15.6 Identification and protection from improper use or disposition.
3.15.7 Reporting to the Government, any GFM or GFE property found damaged, malfunctioning, or otherwise unsuitable for use. In the event of damage or malfunction during or after installation, the supplier must determine and record probable cause and necessity for withholding the material from use. 3.15.8 For GFE material, and as required by the terms of the bailment agreement, the supplier must establish procedures for adequate storage, maintenance, and inspection of bailed Government material.
Records of all inspection and maintenance performed on bailed property must be maintained. 3.15.9 Material returned to the contractor must be handled as GFM. 3.16 Traceability and Certification Requirements - To assure that correct materials are installed in DSSP systems, it is imperative that traceability be maintained from the material to all required Objective Quality Evidence (OQE).
3.16.1 The following provides the minimum requirements for maintaining material traceability and supplements the requirements specified elsewhere in the contract/purchase order. 3.17 Material Traceability - Traceability markings must be permanently applied to the material in accordance with MIL-STD-792 or to a tag affixed to the material, and annotated on the required OQE. The traceability marking may be any vendor traceability number/code which provides complete traceability to the required OQE.
Traceability Marking/Identification may include such items as Nomenclature, Part Number, Technical Description, National Stock Number (NSN), etc. Traceability must be maintained through all process operations including any subcontracted operations, to the finished component. 3.17.1 When traceability markings on the material would be removed by a manufacturing or fabrication process, the marking must be recorded prior to removal and be immediately restored upon completion of the process.
If this cannot be done or is impractical, an appropriate material control procedure (such as a bag and tag, tagging, and/or tote box control) must be employed. The material control procedure must provide a method of positive control to preclude commingling of material or loss of traceability. The traceability marking must be reapplied upon completion of the final manufacturing process.
3.17.2 The material control process must include requirements for the maintenance of traceability for items sent out for subcontracted operations. If such operations would remove traceability markings on the material, purchase or work orders must specify a method and marking location for remarking. The contractor must also ensure that subcontractor production controls are adequate to preclude commingling of materials during processing.
3.18 Final Inspection - The following inspections must be performed prior to Government inspection and acceptance. 3.18.1 Material Sampling - Material must be inspected for form, fit, and function. Lot acceptance must be based on zero defects and lot rejection based on one defect.
The sample size must be in accordance with the sampling plan(s) in the applicable military specification or standard, federal specification or standard, or drawing to which the material was manufactured. In the absence of such sampling plans, sampling inspection must be per ANSI/ASQ-Z1.4, general inspection level II (for sample size selection code), table IIA (for sample size). SMALL LOT SIZES - For lot sizes of fifty or less, the minimum sample size must be eight units.
For lot sizes of eight or less, the sample size must be one hundred percent of the lot. 3.18.2 The Manufacturer may elect to use Statistical Process Control (SPC) to assure product quality in lieu of the above attribute sampling plan, provided that the SPC methodology/system used provides acceptable products to the Government. However, the Government Inspection Activity may perform their acceptance inspection of the material using the attribute sampling plan outlined above.
3.18.3 All OQE required by the Contract and all data concerning material traceability (OQE to traceability marking) must be 100% inspected. The certification test reports must also be 100% inspected for completeness and legibility. 3.19 Test Certification - When test certifications are required elsewhere in the contract, certification documents must be positive and unqualified.
Disclaimers such as "to the best of our knowledge" or "we believe the information contained herein is true" are not acceptable. 3.19.1 If material is received without the required test certification papers or with incorrect/missing data on the certification papers, the material will be rejected. 3.20 See CDRLs DI-MISC-80875 (welding procedures) and DI-MISC-80876 (weld procedure qualification data) - When production or repair welding is required, the applicable welding procedure(s) and qualification data must be submitted for review and approval.
Note: These requirements do not apply to tack/spot welds. 3.20.1 Approval of the Contractor's qualification data must be obtained prior to performing any welding (production or repair). 3.20.2 If the Contractors qualification data has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the procedures and qualification data report to expedite the approval process.
The approval letter must reference the applicable welding procedure and qualification data report identification/number. Prior approval does not guarantee acceptance for this or any future contracts. As far as practical, all procedures for the contract must be submitted at the same time.
Welding procedures and qualification data must be submitted in a commercially available electronic format such as Adobe Acrobat PDF. The contractor must state the applicability of each weld procedure and qualification data submitted, citing the drawing number and pieces to be welded. (i.e.
"WP-123 and QD-123 are submitted for the weld joint between pieces 1 and 2 on drawing ABC." WP-456 and QD-456 are submitted for the hardfacing of piece 3 on drawing XYZ.") 3.20.3 The PCO's authorization for the use of weld procedure(s) and qualification data for the specific application as submitted does not mitigate the vendor's responsibility to comply with the requirements of S9074-AQ-GIB-010/248, S9074-AR-GIB-010A/278, and the contract. 3.20.4 Authority for the repair of Special Repairs in castings, the repair of wrought material, or the repair of forged material must be obtained via request for waiver from the Procurement Contracting Officer. This request must describe the defect; including size, depth, location, and a description of the proposed repair.
Repairs deemed minor or nominal in accordance with S9074-AR-GIB-010/278 can be made at contractor discretion in accordance with S9074-AR-GIB-010/278 requirements; however, Weld Procedure Specification (WPS) and Procedure Qualification Record (PQR) submittals are still required. This request for NAVSUP-WSS Contracts must be submitted via the Electronic Contractor Data Submission (ECDS) application. 3.20.5 Any new procedure qualification performed under this Contract will require the vendor to provide a minimum 72 hour notification to DCMA with an offer to observe the welding of the test assemblies.
The 72 hour time limit may be modified upon mutual agreement between the vendor and DCMA. 3.20.6 Preparation and retention of weld records is required, as specified by paragraph 4.1.3 of S9074-AR-GIB-010A/278. 3.20.7 When production welds or repair welds are performed by a subcontractor, the requirement for submission of all certification documentation required herein must be passed down to the subcontractor.
3.21 See CDRL DI-NDTI-80809 (First Article Testing) - First Article Test/Inspection (Contractor) - The Contractor must conduct ;destructive; First Article Test/Inspection on ;one cable assembly, consisting of one-three contact plug assembly with 90 degree backshell, one-seven contact straight plug assembly, and one conduit 30 inches long; unit(s) in accordance with requirements ;of S-5343934-2 paragraph 4.4; . 3.22 See CDRL DI-MISC-80678 (Special Emphasis C of C) - The certificate of compliance must show traceability to the marking applied on each individual item, and must contain the following information:
- Contractor's name, address, phone number and date. 2.
The contract/purchase order number (i.e. N00104-11-P-FA12) 3.
The national stock number (NSN). The 18 character National Stock Number for Special Emphasis Material includes the two digit COG, the four digit FSC, the 9 digit NIIN, and the two digit SMIC (i.e. 1H 4820 012345678 D4) ("N/A" when Not Applicable).
- Lubricants, sealants, anti-seize, and/or thread locking compounds. ("N/A" when Not Applicable).
- Cure date ("N/A" when Not Applicable). 6.
Manufacturer's compound number ("N/A" when Not Applicable). 7. When weld procedure submittal is required by the contract, a statement that the approval date of the qualification data precedes any production or repair welding performed on this Contract.
("N/A" when Not Applicable). 8. A statement for any Hull, Mechanical and Electrical (HM&E) testing required that include the name of the test and that it was performed satisfactorily.
If no HM&E testing is required, the statement should read "Hull, Mechanical and Electrical (HM&E) testing N/A." 9. A statement to the effect that all items furnished on this contract are in full compliance with the specifications and requirements.
- Contractor's or authorized personnel's signature. 3.22.1 For Connectors, Cables, and Junction Boxes procured to EB Specs S-5343934-1, S-5343934-2, or S-5343934-3, the Certificate Of Compliance must also include the information below:
- A notation that 32 root mean square (RMS) finishes are in accordance with the specifications and are free of imperfections. 12.
Direct reading of O-ring surface diameters with specified standard. 4. QUALITY ASSURANCE 4.1 Notes to DCMA QAR and the Contractor - 4.1.1 DCMA QAR and the Contractor for proprietary designs - Depa...
Clauses and provisions listed on the notice (24)
CONTACT INFORMATION · ITEM UNIQUE IDENTIFICATION AND VALUATION (MAR 2022) · HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (NAVICP REVIEW FEB 1991)(FEB 1999) · SPECIFICATION SECTION C AND E · INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996) · INSPECTION AND ACCEPTANCE - SHORT VERSION · GENERAL INFORMATION-FOB-DESTINATION · WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (DEC 2018) · AND RECEIVING REPORT COMBO · DD FORM 1423 · NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18)) · EQUAL OPPORTUNITY (SEP 2016) · WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003) · DAYS AFTER LAST DELIVERY UNDER THIS CONTRACT · WARRANTY OF DATA--BASIC (MAR 2014) · BUY AMERICAN --FREE TRADE AGREEMENTS--BALANCE OF PAYMENTS PROGRAM - BASIC(DEVIATION 2020-O0019) (MAR 2022)) · NOTICE OF TOTAL SMALL BUSINESS SET-ASIDE (OCT 2020)(DEVIATION 2020-O0008) · ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (NOV 2020) · BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE (DEVIATION 2020-O0019) (JUL 2020)) · BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (NOV 2014) · ANNUAL REPRESENTATIONS AND CERTIFICATIONS (MAY 2022) · NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008)) · 5486641
What this office paid before
USAspending.gov, last 36 months25 awards matched · tier 1: this contracting office (N00104) + PSC 3040. Most recent:
Pro shows every award with the recipient, amount, period and a link to the award record, plus a CSV export. $39/mo.